Monday, June 18, 2007

Butter and Margerine Interesting Facts

Recently we were having a discussion with our new engineers. When we reached the topic shortening plant, which produces margarine, I asked, "What is actually the differences between butter and margarine?" It's funny and embarrassing because I still don't know the differences between those two foods. That's why I asked. Well, I got the answer. However, I would like to share the answers (more detail one) with an article below (Sorry, I forgot where I took this from).
Margarine  was originally manufactured to fatten  turkeys. When it killed the turkeys,
the people who had put all the money into the research wanted a payback
so they
put their heads together to figure out what to do with this product to get
their money
back. It was a white substance with no food appeal so they added the
yellow coloring
and sold it to people to use in place of butter. How do you like
it? They have come out
with some clever new flavorings.


DO YOU KNOW.. the difference between margarine and butter?

Read on to the end...gets very interesting!

Both have the same amount of calories.

Butter is slightly higher in saturated fats at 8 grams compared to 5 grams.

Eating margarine can increase heart disease in women by 53% over eating
the same amount of butter, according to a recent Harvard
Medical Study.

Eating butter increases the absorption of many other nutrients in other foods.

Butter has many nutritional benefits where margarine has a few only because
they are added!


Butter tastes much better than margarine and it can enhance the flavors of
other foods.


Butter has been around for centuries where margarine has been around for
less than 100 years.


And now, for Margarine..

Very high in trans fatty acids.

Triple risk of coronary heart disease.

Increases total cholesterol and LDL (this is the bad cholesterol) and lowers
HDL cholesterol, (the good cholesterol)


Increases the risk of cancers up to five fold.

Lowers quality of breast milk.

Decreases immune response.

Decreases insulin response.

And here's the most disturbing fact.... HERE IS THE PART THAT IS
VERY INTERESTING!


Margarine is but ONE MOLECULE away from being PLASTIC.

This fact alone was enough to have me avoiding margarine for life and
anything else that is hydrogenated this means hydrogen is added,
changing
the molecular structure of the substance).


You can try this yourself:

Purchase a tub of margarine and leave it in your garage or shaded area.
Within a couple of days you will note a couple of things:


* no flies, not even those pesky fruit flies will go near it (that should
tell you something)


* it does not rot or smell differently because it has no nutritional value;
nothing will grow on it Eventhose teeny weeny
microorganisms will
not a find a home to grow. Why? Because it is nearly plastic. Would

you melt your Tupperware and spread that on your toast?

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Friday, June 15, 2007

Cooling Tower Target Nozzle

As promised, I'll share some informations about target nozzle which is among vital parts of a cooling tower. A target nozzle looks like the photo beside. That is a "Counterflow Nozzle Orifice" (sizes available from 1/2" - 1 1/2). A target nozzles function is to sprinkle the warm cooling water to increase its surface area (for heat transfer with air) before it goes down from the deck to the water basin. It is usually an injection molded polypropylene unit consisting of two parts—the main body with integral target diffuser and a snap-on insert or orifice cap. A cooling tower deck may have up to 200 or more target nozzles.

All this while I only know this type of target nozzle. After researching in the internet, I found there are various other types of target nozzles.

The first type (left) is a Counterflow Nozzle - 2" NPT Thread, (Orifice sizes 1/2" - 2"); the second (mid) is the a counter-flow down-spray nozzle; Square-Pattern, Full Coverage Type, 1-1/2" Standard Pipe Thread Connection; and the third (right) is a counter-flow up-spray Nozzle, fits 1-13/16" Diameter Hole in PVC pipe. There are more types of target nozzles at CoolingTowerNozzles.com.

To learn more about target nozzles, check out the following sites:
spxcooling.com
ceshepherd.com
coolingtowerresource.com

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Tuesday, June 12, 2007

Cooling Tower FRP Water Distributor

What you can see in the photo is a cooling tower deck. This is where warm cooling water from processing plant arrives. The warm cooling water will then be evenly distributed on the light blue colour FRP (Fiber Reinforced Plastic) deck by a water distributor. The warm cooling water will then falls underneath the deck through the target nozzle holes. You can see there are plenty of small black round shape holes on the deck. The target nozzles are important to sprinkle the water before it goes further down to increase its surface area (I'll show and explain about target nozzle in future post). The warm cooling water will then be sprayed over a fill in the cooling tower to increase the contact area, and air is blown through the fill. Majority of heat removed from the warm cooling water is due to evaporation. The remaining cooled water drops into a collection basin and is recirculated to the plant (for chiller or heat exchanger). Typically, the temperature drop is 10oC.

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Monday, June 11, 2007

How Do You Analyze Your Heat Exchanger Performance?

I have more than 10 plate heat exchangers (PHE) in my plant. Usually, we'll monitor the flowrate, inlet and outlet temperature, as well as pressure. Before, I joined the company, I observed that the "cleaning in place" (CIP) using caustic solution was carried out when the PHE could no longer produced desired flow rate and temperature outlet. This is one method of eliminating the fouling and scaling on the plate surface in order to improve the heat transfer. If CIP does not work, we have to dismantle the PHE, clean the plates in hot caustic and attach new gasket on it. This will be a far more expensive option and take longer time.

To avoid massive fouling and scaling from getting worse, we have to conduct CIP regularly. When is the right time to perform CIP? As mentioned above, when the flow rate is low or desired outlet temperature could not be achieved, we shall consider doing CIP.

However, I came out with a formula to calculate the "Overall Heat Transfer Coefficient" (U-value) of the heat exchanger. The U-value will give me some indication on which heat exchanger is providing the worse heat transfer. By simplifying the formula in excel file, I can easily know which heat exchanger needs attention just by inserting the inlet/outlet temperature, mass flow rate, heat capacity of oil, and surface area of the plates. The LMTD (log mean temperature difference) will be obtained from the formula and further applied to get the U-value.

I use and manipulated the following formulas:

Q = mc(theta) = UA(LMTD)

Can you work out the formula?

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Thursday, June 7, 2007

Preparation Work For New Plate Heat Exchanger

Earlier this year, I ordered a set of plate heat exchanger (Schmidt-Bretten brand). We desperately need another plate heat exchanger (PHE) as a back-up unit to those that we presently have in plant. I have to correctly specify the specifications of the PHE as it is not a cheap piece of equipment. Thank God, everything was OK and we'll be expecting the PHE this coming August.

However, the job does not end there. I have to plan and prepare for the piping layout and other related civil work. I need to order additional parts/equipments/instruments such as globe valves, ball valves, drain valves, control valves, pipes, RTD's, pressure gauges, vortex flow meters, temperature gauges, steal plates, bellow seals, bolts and nuts etc. (those items are very expansive!!! especially the globe valve...). We have to get all the piping ready before the PHE arrive. We need to complete it in less than 2 months from now. I pray and hope everything will run smooth for this small project of mine.

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Tuesday, June 5, 2007

Spiral Heat Exchanger

In my plant, there are two small spiral heat exchangers which function as a shutdown cooler. I'm not sure what is the capacity and specifications of it. I have no experience using or operating them. But, I'm interested to learn about them.

Spiral heat exchanger differs a lot from plate heat exchanger (PHE). There are also pros and cons using spiral heat exchanger compared to PHE. From my limited experience, a spiral heat exchanger require less maintenance. There is no plates and no internal gaskets. To clean the internal part, a "cleaning in place" (CIP) is carried out using caustic solution up 60-75oC. The spiral heat exchanger is totally stainless steal solid and it is very heavy. One problem that can make a spiral heat exchanger useless (or very expansive to repair) is when the internal wall crack or leak. When this happen, the fluids entering the spiral heat exchanger will mixed and hence affect the production quality (reject!!!).

Spiral Heat Exchangers exhibit ideal heat transfer and fluid handling characteristics for a wide range of applications.
  • Takes up only one sixth of the space
  • Means lower costs for buildings, pumps valves and piping
  • Uses 75% less pumping energy
  • Provides higher K- value and a close temperature approach
  • Ensures continual self-cleaning effect for maximum operating efficiency
Nowadays, there are very few companies selling spiral heat exchanger compared to PHE.
For further references on this type of heat exchanger, check out Alfa laval and Heseco.


Example of a big spiral heat exchanger. The mass of it is about 5 tonnes.

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Monday, June 4, 2007

Chemical Engineering World 100 Readers

Earlier this year, I set a target to get 100 readers by the end of 2007 for Chemical Engineering World blog. Today, the feedburner chicklet in this blog shows 101 number of readers. I'm so pleased and delighted with the progress so far and thanks for the support from all of you. I managed to achieve the target six month ahead. Next month, this blog will celebrate its first anniversary and that is another achievement from my side. Time is running very fast that I did not realize it's almost one year since I started blogging about work - chemical engineering. I must admit I just discovered blogging last July and luckily I subscribed to a broadband that time. The next thing happened, this blog was created.....

Despite being pretty busy with my daily hectic job (especially the first week of every month...I have to do detailed production/utility report), I'm trying my best to share some pieces of my working and life experiences related to chemical engineering on a more consistent basis. This is a real challenge for me as time is usually not on my side. I hope I can work more efficiently and effectively, and at the same time allocate some quality time with my family, because being a balanced human being is part of my philosophy. I don't want my life to be concurred by my JOB, although I like and appreciate it. Hence, I just want to continue working and do the best for my employer. At the same time, I'll establish myself as a profound engineer and add up some essential skills while working here.

It's part of my target to educate and provide valuable information to others especially chemical engineering students and junior chemical/process engineers via this blog. I'm doing this simply because when I was a student, I never had a slight picture on how a chemical engineer works and what is the industry like. Now, as I'm a practicing engineer, I want the youngsters to know, to learn, to be exposed....

I thanked and welcome positive and negative comments from fellow readers all around the globe. I did received a lot of great feedbacks and encouragement. Thanks to you guys. It made me want to contribute (posting) even more. I also have some collaborations going on with few parties which I never expected to happen. I hope more collaborations can take place and produce more success.

Ooooh...about the photo, it's actually nothing really related to this blog niche. It's just "snake-like green pepper". The green (red) pepper is from Shanxi, China and it resemble a snake like creature. It does look like a chilly in a distorted pepper....that's what I can see. (p/s I hope I can be a chemical engineer growing some crops (such as chillies, tomatoes, cucumber, sugar cane, etc....later in future)).

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.