Tuesday, July 3, 2007

Oil and Gas - Optimizing Mature Assets

The following information is more towards the Oil and Gas field, especially exploration and production area. Check out the infos that was delivered to my mailbox.

Hart Energy Publishing and E&P are pleased to announce that RPSEA will co-present BOMA 2007. Hart Enery Publishing and E&P Magazine announce the Research Partnership to Secure Energy for America (RPSEA) has agreed to co-present the 3rd annual Optimizing Mature Assets (BOMA 2007) on November 1, 2007 at the Hyatt Regency in Houston. So, if you happen to be around that area, drop by and check out the convention.

RPSEA is a non-profit corporation formed by a consortium of premier U.S energy research universities, industries and independent research organizations. RPSEA's mission is to provide a stewardship role in ensuring the focuses research, development and deployment of safe, environmentally sensitive technology that can effectively deliver hydrocarbons from domestic resources to the citizens.

BOMA 2007 will explore opportunities for mature asset optimization offshore. Also discussed will be the emerging problems in mature offshore fields, such as sustained casing pressure, in addition to emerging technical solutions.

Major topics at BOMA 2007 will include:

- Prospectivity in Mature Areas
- Reservoir Imaging and Modelling
- Regional Prospectivity
- Re-entry and Infill Drilling
- Evolving Business Models
- Well Intervention
- HSE Issues
- Infrastructure Issues
- Regulatory Issues
- Maturation of Deepwater fields
- Emerging Technology for Mature Assests

Preliminary Agenda:

Click here to view the Agenda. Register now by clicking here.

Saturday, June 30, 2007

Bypass Line Configuration

There will always be a bypass line in a process plant. However, are you having the correct bypass line set-up? A bypass line set-up is different if the line is used for steam or oil or slurry. If you are using the bypass for a steam line, you can have the bypass line at the bottom of the main line. You must also have a steam trap installed as well on that bypass line to ensure condensate water is released when necessary.

What if you have a slurry line? I was checking my email and found the Cheresources newsletter that tells about this. The bypass lines should be placed above the control valve (as shown in the photo) so that the slurry cannot settle out and build up in the line during bypass. In addition to that, slurry lines should be sloped 1/2" for every 10 feet of horizontal pipe to avoid settling. Actually the steam line should have certain degree of slope to hinder water from settling and further create water hammering which can destroy the pipeline.

Thursday, June 28, 2007

Danfoss Inverter - Save Your Power

I attended a training on Wednesday. It was a training about inverter conducted by Danfoss. Danfoss is a big company based in Denmark producing various products. The trainer (product manager) was really well prepared. We were given a file complete with colourful brochures and slides as well as papers to jot down note. The introduction of the presentation was very well define. The presenter informed us the flow of presentation together with the expected time (in minutes) for each topic. All together 120 minutes (2 hours). That's good. At least we know when the training will end.

The training commenced with a short 5 minute video introducing Danfoss. It was a very impressive and informative presentation. They really have state of the art technology (which utilizes efficient and effective robots) to manufacture inverters as well as other products.

Inverter can save power and money (reduces maximum power demand). In addition to that, it can lengthened the life span of your motor and other equipments. It reduces start current and reduces start torque by the square of the current reduction. Inverter actually reduced voltage starting attempts in a motor and avoid it to start instantaneously. Inverter will slowly and gradually supply the voltage and current to a motor until a maximum level.

There are more to discuss about inverters. Inverters are really impressive in saving power. A lot of process plant are installing and utilizing inverters. I shall discuss more about it in a few days time.
Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Tuesday, June 26, 2007

Don't Panic! I'm Renovating This Site

If you are a regular visitor to this blog, you might be surprised by this moment. It's not dark black anymore... I'm in the process of improving and changing the look of this blog. It may take a few days for me to get everything in place. For the time being, you might see that this blog is missing a lot of its links and other contents. Don't worry, it will be back to normal soon.

I'm doing some improvement in this blog. I'm introducing a new face lift or theme for this blog. I hope it looks more appealing than before. Thanks to Gecko and Fly for the new template of this blog. In addition to that, I'm inserting few more pages to this blog: "links", "jobs", "books", "magazine", contribute" and "search". I hope with those pages, this blog will be more organize instead of everything being packed in one single page. Feel free to check out and utilize those pages. However, I'm still improving and upgrading, adding more content to those pages. So, I apologize if the pages are not perfect yet or still under construction when you visit/click them.

If you are a new visitor to this blog and have great interest in anything associated with Chemical Engineering, then this is the perfect site for you. Learn stuff about Chemical Engineering that is not in your text book such as heat exchanger, cooling tower, boilers, oil and gas updates, conferences and much more. Don't miss any post. Subscribe to this blog and get email updates or RSS feeder. To know me slightly better, go to the "about" page. I've a little summary about myself and my career.

Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Monday, June 25, 2007

Oil and Fats International Congress 2007 in Cairo

My job is not flexible enough to allow me to visit the recent Oil and Fats International Congress (OFIC) 2006 in Cairo last March. That's fine. Even if I can go, I don't have the budget!!! If I'm a researcher and I have a research grant and have a paper to present, then I can probably go. I participated in OFIC 2006 in Kuala Lumpur last year. Check out my previous post:

I'm back from the Congress
OFIC 2006 Exhibition
OFIC 2006 Modules

Enough about that, back to OFIC 2007. The aim of the conference was to provide a good overview of the edible oils and fats industry by covering current processes and products together with a look at future trends. Expert speakers were invited from all over the world. Day 1 focused on raw materials and their processing, and Day 2 on applications, both industrial and consumer products. Other subjects covered included quality control, crystallisation , labelling and nutrition.

A colleague of mine from Taiko Clay who went to OFIC 2007 in Cairo was kind enough to email me the link to the list of papers/slides presented during the conference - soci.org.

Among the interesting topic covered during the conference are:

Production and Processing - An Overview of Future Trends
Ken Carlson, Crown, USA

Potentials in Bleaching Earth Reduction - Theoretical Background, Industrial Results
Gunter Börner, OHMI Engineering, Germany

Formulation and use of Frying Oils
Adam Thomas, AarhusKarlshamn, UK

Life Cycle Assessment of Vegetable Oils & Spreads
Erich Dumelin, Unilever, The Netherlands

There are a lot more fantastic and informative titles. Check out soci.org.
The next OFIC 2007 will be held in China. Are you going??
Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Saturday, June 23, 2007

Vacuum Dropped Alert!!!

The entire week have been an interesting. Besides my routine job, I learned and experienced new things. However, I will share only the following 3 stuffs.


Vacuum dropped due to wet steam

I hate this case!!! When vacuum pressure dropped, the quality of oil is affected and most of the time the oil have to be rejected. In this case, vacuum dropped occurred because of wet steam. Wet steam is basically water carry over from boiler. Boiler is supposed to produce steam and deliver it to plant. When boiler began sending steam + water to the plant (which is not suppose to happen), the vacuum system is interrupted. The vacuum lost its capability to suck fatty acid which is supposed to be removed from the oil. I could not let it happen again. I don't want my plant to reject oil again because of this 'typical' reason. The boiler people never want to admit that they sent steam + water to the plant.

Therefore, I decided to investigate the case further. Few minutes after the 3rd incident ocurred (wet steam) I took a bottle of condensate water sample (this is the condensed steam which became hot water) and tested its TDS (total dissolved solid). We tested the TDS using a digital TDS meter at the boiler house. The TDS of the sample showed 70 ppm. Normal condensate water should display reading less than 10 ppm. This implied that water carry over (wet steam) happened. Why? Because, steam is water (H2O) at 120 ++oC temperature (around 15-17 bar). Hence the boiler is/should only send steam (pure H2O). Pure H2O should have zero or very minimum content of metal/solids/substance inside it. When steam condensed and became condensate water, the content of metal/solids/substance should remain. However, when wet steam occurs (due to water level fluctuation inside the boiler), some water follows the steam to the plant. The water is chemically treated and this increased its TDS. Therefore, if the condensed water is 'rich' of TDS, this confirms that wet steam is taking place.

Up to today, I gathered 2 condensate water samples (as proof) after the wet steam incident and the TDS result is very high!!! The boiler people definitely have to do something to avoid this from worsening or happening again. I'm not accusing anybody to be responsible of the "oil rejection". I sincerely just want to solve the problem. Save cost and time as well.


Checking the Total Dissolved Solid (TDS) at different temperature

When I first checked the condensate water sample which was collected by my supervisor, it showed TDS of 67 ppm. The boilerman said, that is impossible. He claimed that my sample was very cold (I left the sample in my office for about 5 hours before testing it. Therefore the air condition has cooled down the condensate water temperature to about 24-27oC). That's fine....I told him, let's heat the same sample up to 65-70oC and repeat the TDS test. We heated up the sample and re-tested the sample at 65oC. The sample showed reading around 70ppm. At least, it's close the the earlier TDS reading. Before repeating the TDS test, I told the boilerman that TDS have nothing to do with temperature. However, he stubbornly claimed that temperature influenced the TDS reading. After that he kept quiet and admitted that temperature have nothing to do with TDS. Hence, the condensate water really have high TDS which means water carry over (wet steam).
Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
Or you can also
Subscribe to CHEMICAL ENGINEERING WORLD by RSS.

Wednesday, June 20, 2007

Getting A Hoist

I need a hoist in the store (warehouse) to lift pallets and other heavy stuffs efficiently. Therefore, I looked and searched for companies selling hoist. After calling and requesting quotations from few companies (selling hoist), I browsed the net to have a sneak peak on those companies to see what are the products and services they have to offer. It was very interesting to see that there are various types of hoist with various applications and various funny names too. I never knew that hoist have a lot of "species!!" I don't have much time to go through all of the hoist informations, but I'm glad I learned few of them.



Check out some definitions of hoist incase you want to know literally what a hoist is:

  • raise or haul up with or as if with mechanical help; "hoist the bicycle onto the roof of the car"
  • move from one place to another by lifting; "They hoisted the patient onto the operating table"
  • raise; "hoist the flags"; "hoist a sail"
  • lifting device for raising heavy or cumbersome objects
    wordnet.princeton.edu/perl/webwn

  • "A hoist is a device used for lifting or lowering a load by means of a drum or barrel around which rope or chain wraps. May be manually operated, or electrically or pneumatically driven and may use chain, or fiber or wire rope as its lifting medium."
    en.wikipedia.org/wiki/Hoist

    "A mechanical lifting device usually attached to a trolley that travels along a bridge, monorail, or jib crane."
    www.steelbuildinghelp.com/steel_buildings_glossary_h-i-j.htm



    Some companies selling hoist:
    harringtonhoists.com (USA)
    hoistlift.com (USA)
    www.grainger.com
    mstime.com.my (Malaysia) >>> Interesting flash preview!! There are a lot of interesting names for their hoists: "Street, Donati, Italkrane, JD neuhaus, MS Herkules and Daesar."

    Very interesting too....There are a magazine "specializing in hoist"
    Check out hoistmagazine.com
    Enjoyed this post? Subscribe to CHEMICAL ENGINEERING WORLD by email.
    Or you can also
    Subscribe to CHEMICAL ENGINEERING WORLD by RSS.